Process Calibrators
Fluke 717 Pressure Calibrator

– Measure pressure, 0.05% of full scale with internal sensor up to 5000 PSI/345 bar sensor
(5000G model)
– Measure mA with 0.015% accuracy and 0.001 mA resolution, while sourcing 24V loop power
– Measure pressure to 10,000 psi/700 bar using one of 29 Fluke 700Pxx Pressure Modules
– 1/8 NPT female pressure fitting
– Compatible with non-corrosive Gases and liquids
– Select eleven different engineering units
– Zero, min, max, and hold functions
– Calibrate P/I instruments with simultaneous pressure and current measurement
– Pressure switch test function captures set, reset and Deadband values of a pressure switch
– Error% calculation of mA measurements for quick pass-fail decisions
– Long lasting battery life
– Holster features test lead storage
– Compatible with Toolpack magnetic hanging system
– New switch test

    Description

    The Fluke 717 Pressure Calibrators delivers outstanding performance, durability and reliability. These calibrators are compact, lightweight, and easy to carry. With a push button interface similar to the multifunction Fluke 740 Series Documenting Process Calibrators, the 717s are easy to use. They are EMI tolerant, dust and splash resistant, and feature a removable battery door for quick battery changes.

    These calibrators come in 9 models measuring pressure up to 5000 psi/345 bar and are compatible with Fluke 700Pxx differential, gauge and absolute pressure modules to increase functionality.

     

    Specifications
    Loop PowerRange: 24 V dc
    Accuracy: +/- 10%
    Note: Drive; 20 mA into 1000 ohms for battery >6.8V; 700 W for battery 5.8 to 6.8 V
    DisplayClear 5 digit LCD

     

    Environmental Specifications
    Operating Temperature-10 ºC to 55 ºC
    Storage Temperature-40 ºC to 60 ºC
    Humidity (Without Condensation)95% (10 ºC to 30 ºC)
    75% (30 ºC to 40 ºC)
    45% (40 ºC to 50 ºC)
    35% (50 ºC to 55 ºC)
    Operating Altitude3,000 M max

     

    Safety Specifications
    SafetyCSA C22.2 No. 1010.1:1992

     

    Mechanical & General Specifications
    Size201 mm L x 98 mm W x 52 mm (7.93in. L x 3.86in. W X 2.06in.)
    Weight22 oz, approximately 600G with holster
    Warranty3 Years
    Shock & VibrationRandom, 2G, 5-500z
    1m drop test
    Battery typeSingle 9V battery ANSI/NEDA 1604A or IEC 6LR619V alkaline

     

    Measurement Accuracy
    Pressure717 Series
    Measure Pressure: Internal Sensor
    Accuracy: 0.05% full scale
    Functions: Zero, Min, Hold, Damp Note Gasses / Liquids (non-corrosive)Fluke 717 1G
    Range: -1 to 1 PSI, (-68.9 mbar to 68.9 mbar, -83 to 6.89 kPa)
    Resolution: 0.0001 PSI, 0.001 mbar, 0.0001 kPa
    Over Pressure: 5 X Full ScaleFluke 717 30G
    Range: -12 to 30 PSI, (-850 mbar to 2 bar, -83 to 206.84 kPa )
    Resolution: 0.001 PSI, 0.1 mbar, 0.01 kPa
    Over Pressure: 2 X Full ScaleFluke 717 100G
    Range: -12 to 100 PSI, (-850 mbar to 7 bar, -83 to 689.48 kPa)
    Resolution: 0.01 psi, 0.1 mbar, 0.01 kPa
    Over Pressure: 2 X Full ScaleFluke 717 300G
    Range: -12 to 300 PSI, (-850 mbar to 20 bar, -83 to 2068.42 kPa )
    Resolution: 0..01 PSI, 1 mbar, 0.1 kPa
    Over Pressure: 375 PSI, 25 barFluke 717 500G
    Range: 0 to 500 PSI, (0 mbar to 34,7 bar, 0 to 3447.38 kPa )
    Resolution: 0.01 PSI, 1 mbar, 0.1 kPa
    Over Pressure: 2 X Full ScaleFluke 717 1000G
    Range: 0 to 1000 PSI, (0 mbar to 69 bar, 0 to 6894.76 kPa )
    Resolution: 0.1 PSI, 1 mbar, 0.1 kPa
    Over Pressure: 2 X Full Scale

    Fluke 717 1500G
    Range: 0 to 1500 PSI, (0 bar to 103.4 bar, 0 to 10342 kPa )
    Resolution: 0.1 PSI, 0.01 mbar, 1 kPa
    Over Pressure: 2 X Full Scale

    Fluke 717 3000G
    Range: 0 to 3000 PSI, (0 bar to 207 bar, 0 to 20684.27 kPa)
    Resolution: 0.1 PSI, 0.01 bar, 1 kPa
    Over Pressure: 2 X Full Scale

    Fluke 717 5000G
    Range: 0 to 5000 PSI, (0 bar to 345 bar, 0 to 34474 kPa)
    Resolution: 0.1 PSI, 0.01 bar, 1 kPa
    Over Pressure: 2 X Full Scale

    Fluke 717 Series with Pressure Modules
    Measure Pressure: (via  pressure module connector using optional Pressure Modules)
    Range:
    Resolution:
    Accuracy:
    Functions:

    CurrentRange: 0 to 24 mA (-25% to 125%)
    Resolution: 0.001 mA
    Accuracy: 0.015% + 2 counts